- 2016 to 2020: Q80021801 - The ARC-8050T3-12 needs to partition it in Disk Utility it says the partition
Answer: macOS 10.13's Disk Utility 17.0 (1626) does not recognize unformatted disks unless you click View > Show All Devices, quit Disk Utility, then relaunch it. But Diskutil does ... - 2018 to 2020: Q10021807 - I receive the message "No BIOS disk found. RAID Controller BIOS not installed"
Answer: Raid BIOS will be installed only if there has bootable volume existed. If your volumes are created by 4Kn drives, it is not bootable. Please check ... - 2018 to 2020: Q10071807 - We have an ARC-1883i controller which gives below errors without slot number?
Answer: ... - 2018 to 2020: Q10081807 - ARC-1883x with Lenovo D3284 drive system can see the SAS expanders which are
Answer: Please update ARC-1883x firmware to 1.54-20180619 or later for this compatible issue. ... - 2018 to 2020: Q10091807 - Is there any compatible issue with Toshiba 14TB disk drives (MG07ACA14TE)?
Answer: The only issue appears to be an Initialization Mode such as Foreground Initialization. While the initialization starts OK it fails after less than 2-3 minutes. ... - 2018 to 2020: Q10101807 - ARC-9200 firmware is not able to register the Hitachi Ultrastar 4U Data102 we
Answer: Controller firmware reserved resource is not big enough for the Hitachi Ultrastar Data102 4U 102 bay JBOD. Please update firmware to 1.55-2018-0619 or later for ... - 2018 to 2020: Q10031808 - Does ARC-1883 boot from the 4Kn disks?
Answer: 4kn boot ability is supported by UEFI bios only. Your motherboard must support UEFI bios code if you would like to boot up from a volume ... - 2018 to 2020: Q10051808 - I have two WD4000FYYZ HDD, one Error Recovery Control seems disabled, other enabled.
Answer: Controller will follow the setting the drive reported. The new drive could show disable if it is default disabled. You can modify the TLER setting ... - 2018 to 2020: Q10071808 - Why enable the “Read And Discard Parity Data” option on the ‘Advanced Configuration”
Answer: The “Read And Discard Parity Data” is used to determine if parity data is to be read and discarded. Enable this setting has better read ... - 2018 to 2020: Q10011811 - My degraded RAID set immediately claimed the inserted fully working HFS+ drive as
Answer: In our design, we think that controller recovers a degraded volume at the first priority, so the default setting will automatically rebuild a degraded volume if ...
The most popular searches are:
- firmware timed out⊂mit=Search (78241x)
- upgrading raid card⊂mit=Search (76220x)
- Greater Two TB Volume Support⊂mit=Search (55433x)
- Greater Two TB Volume Support (50132x)
- upgrading raid card (26691x)
- firmware timed out (21679x)
- hitachi failed drive (14539x)
- upgrading+raid+card (14452x)
- hitachi failed drive⊂mit=Search (14426x)
- Greater+Two+TB+Volume+Support (11221x)