Q60012009 - How to solve the “Volume for BBM – Mismatch” message shows on the ARC-9200 event log, and always showing “initializing” for the dual controller status.


It is a status for FBM not proper power up/down. So the NVRAM remembers what it had before and trying to “recovery”.

Resolution:

  • Remove the front cover with 2 thumb screws
  • Disconnect both BBU cables.
  • Power Up, and make sure they are “dual operational”.
  • Then power down, and reconnect both BBU cables.
  • Tighten up the 2 thumb screws again,
  • Power up again.

 

 

 

Tags: ARC-9200, BBM, FBM
Last update:
2021-02-04 10:56
Author:
Simone
Revision:
1.1
Average rating:0 (0 Votes)

You cannot comment on this entry

Chuck Norris has counted to infinity. Twice.

Records in this category

Tags