Q10041301 - I have gotten the following event message on the ARC-1680ix controller.
> 2012-04-20 03:11:20 Enc#2 SLOT 06 Device Removed
> 2012-04-20 03:11:19 Enc#2 SLOT 06 Device Inserted
> 2012-04-20 03:11:12 Enc#2 SLOT 06 Time Out Error


The Time Out Error HDD will cause the SAS PHY loss and link again if our firmware sends the reset command to the HDD. It has fixed by ARC-1680ix firmware version 1.51 date: 2012-6-14 or later.

Tags: ARC-1680ix, firmware