ID #1826
Q40011911 - Is this possible with the ARC-9200 and if it is possible to send signal by protocol Modbus TCP/IP to SNMP server in case of failure”?
All our controllers do not support Modbus protocol.
Tags:
ARC-9200
,
SNMP
About this FAQ
Rate this FAQ
Last update:
2020-08-25 11:10
Author:
Simone
Revision:
1.0
☆
☆
☆
☆
☆
Average rating:
0 (0 Votes)
Arabic
Basque
Bengali
Bosnian
Brazilian Portuguese
Chinese (Simplified)
Chinese (Traditional)
Czech
Danish
Dutch
Finnish
French
French (Canada)
German
Greek
Hebrew
Hindi
Hungarian
Indonesian
Italian
Japanese
Korean
Latvian
Lithuanian
Malay
Norwegian Bokmål
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swedish
Thai
Turkish
Ukrainian
Vietnamese
Welsh
Start translation...
You cannot comment on this entry
Your name:
Email
Your comment:
Please enter the captcha code
submit
Records in this category
Q40011602 - ST4000NM0033 Seagate enterprise HDD can’t pass self test of ARC-8008 RAID controller shown randomly time out error, when system powers on.
Q10051603 - Set "HDD Low power Idle" to "7" and test. Then reset to "Disabled" again, but the setting is stuck.
Q40011603 - What is the max CPU Temperature of the ARC-5066 or at which temperature it starts to log and throttle?
Q10011605 - CLI is showing garbage Slot# larger than 32 when the Disk Info command is issued to HGST JBOD 4U60.
Q10021605 - Is there a way to tell RAID controller hardware revision in software?
Q10031605 - The ARC-1883ix appears to scroll though the disks in the Quanta M4600H JBOD until it hits the disk drive in slot 49.
Q10041605 - The ARC-1883ix is hanging on a particular slot when booting the HGST 60 Bay. Removing and reinserting the drive in the particular slot to allow the ARC-8781 boot process to complete.
Q40011607 - Do Areca external RAID controllers support SED drive with encrypted function?
Q40011609 - We need to remove the Guest account access on the RAID card GUI. (Username=Guest, Password=Guest)
Q40011703 - ARC-8008 RAID controller cannot see any HDD when HGST JBOD 4U60 is set as SES mode.
Q40021703 - Areca RAID Hierarchy shows disk drive numbering different from “Drive Location” label on the HGST JBOD 4U60.
Q40011705 - Do current GA versions of vSphere and VSAN support 4K Native drives?
Q40011706 - Firmware V1.54 2016-05-13 Alarm By Mail function sends incorrect day of week.
Q40011710 - Does the Areca SED function support conform to the Trusted computing Group specifications Opal, Enterprise or both?
Q40011712 - The ArcSAP utility keeps crashing when I try to open it.
Q40011802 - macOS 10.13 High Sierra Security requires a user’s approval before loading third-party kernel extensions.
Q40011805 - I am getting a random 3.3V over voltage error on ARC-5088 RAID controller.
Q40011807 - ARC-9200 firmware is not able to register the Hitachi Ultrastar 4U Data102 we have here.
Q40021807 - 4U60G2 through ARC-9200, Single controller becomes disabled when it loses connection to JBOD. How can we reactivate it?
Q40031807 - Is it possible to support dual LCD function if the 8088-2S is in a dual-controller mode?
Q40041807 - No hardware information displayed on slave unit (controller-2) when ARC-8088-SAS is working dual controller mode.
Q40011811 - ATTO Expresssas H1280 can not work with ARC-8380 SAS RAID subsystem. When we try to write information to the drive it becomes unresponsive. We can web browser ok with no errors and have tried both SAS ports on the SAS card and the Raid unit.
Q40011903 - When ARC-8050U3-6 USB-C raid enclosure plugged into the super micro mother board it is not allowing the M/B to boot.
Q40021903 - The ARC-8050U3-6 is powering down after certain time during foreground initialization even if HP spectre 360 is on and working.
Q40031903 - How to disable Windows 10's 'USB selective suspend' setting?
Q40041903 - Can ARC-8050U3-6 support multiple volumes?
Q40011907 - How to configure the SSL and port settings on the ARC-SAP email setting?
Q40021907 - The ARC-SAP email is working officially using Office365 (Microsoft) for the notification.
Q40031907 - I can’t make the ARC-SAP in Windows 2019 to send with gmail server.
Q40011908 - What is the maximum HDD capacity of Areca RAID controller’s firmware?
Q40011909 - ATTO H1280 PORT A can’t detect the volume on the ARC-7212 SAS RAID subsystem.
Q40011910 - What is the max no. of SAS expander and enclosure Areca firmware supported?
Q40011911 - Is this possible with the ARC-9200 and if it is possible to send signal by protocol Modbus TCP/IP to SNMP server in case of failure”?
Q40011912 - When commissioning an ARC-8070 new volume under Linux, a number of index tables (I-node tables) are distributed over the entire volume.
Q40011912 - When commissioning an ARC-8070 new volume under Linux, a number of index tables (I-node tables) are distributed over the entire volume.
Q40012003 - For ARC-8608-4 32G FC D.B, 16Gb SFP detect and working normal but 8Gb SFP detect unknown.
Q40012009 - How to solve the “Volume for BBM – Mismatch” message shows on the ARC-9200 event log, and always showing “initializing” for the dual controller status.
Q40012012 - ARC-8050U3-6 can’t startup when it has not any HDD installed.
Tags
12Gb/s SAS expander
4KN drive
Acronis
Advanced Data Mirroring
AJA
Alert By Mail Configuration
ALUA
AOC
API
ARC-1035
ARC-1130
ARC-1200
ARC-1201
ARC-1202
ARC-1203
ARC-1203-2I
ARC-1210
ARC-1212
ARC-1213
ARC-1213-4i
ARC-1214
ARC-1214-4I
Arc-1214-8I
ARC-1220
ARC-1221
ARC-1221x
ARC-1222
ARC-1223
ARC-1223-8i
ARC-1223-8X
ARC-1224
ARC-1224-8I
ARC-1225-8I
ARC-1230-8x
ARC-1231
ARC-1231Ml
ARC-1260
ARC-1261ML
ARC-1264il-12
ARC-1264il-16
ARC-1280
ARC-1280ML
ARC-12x3
ARC-12x4
ARC-12x5
ARC-12x6
ARC-1300
ARC-1300-4e
ARC-1300-4i
ARC-1300ix-16