- 2014: Q10121404 - Can I expand the capacity of the raid by hot swapping each drive
Answer: There has one additional Clone Disk function from firmware version 1.52. You can use this clone disk function to replace one by one. After you clone all ... - 2014: Q10011405 - ARC-1214 reports that ST4000VN000 Current SATA Mode is SATA150+NCQ (Depth32) but not SATA600+NCQ
Answer: Seagate ST4000VN000 6G SATA drive SC44 firmware manufacture current allowance speed default set on 1.5Gb/s even its capability=6Gb/s. This issue can be solved by manually configuring drives to ... - 2014: Q10021405 - ARC-1882 can not detect the ST4000VN000.
Answer: Seagate ST4000VN000 6G SATA drive SC44 firmware manufacture current allowance speed default set on 1.5Gb/s even its capability=6Gb/s. The PL firmware phase 17 or later can not work with ... - 2014: Q10041406 - When trying to update the ST3000DM001-9YN166 hard drive firmware from CC4C to CC4H
Answer: Hard drive firmware must be repacked to be able to update through our manager console. If you would like to update hard drive firmware through ... - 2014: Q10011407 - Is there a problem with a 4KN drive or can I only use
Answer: Firmware version 1.52 date: 2014-04-02 has supported 4KN drives, but you must make sure your OS also supports 4KN drives. Volumes created by 4KN drives will use same ... - 2014: Q10021410 - I am getting a lot of smart ID 199 CRC_Error_Count for drive in
Answer: The default signal strength of this port may be not good enough for this SSD. You can adjust the signal strength of this specific port through ... - 2014: Q10101410 - Does ARC-1883LP controller support a drive connected on the expander out port from
Answer: Areca's LED lighting function via SES2 protocol. In case hard disk didn't response RAID card a SES2 information on SES2 mode then hard disk will be failed. Firmware version 1.52 date: 2014-10-28 or later allows device directly connected expander out port recognized by RAID controller. ... - 2014: Q10061412 - Controller fails the brand new hard drive when runs the Hdd Xfer Speed function.
Answer: The problem is that the drive is not initialized, so it does not carry overwrite-repair action on factory bad bock and cause the read errors. First, you must initialize the drive, and then it will allow you to run Hdd Xfer Speed function. ... - 2014: Q10091412 - ARC-1883 reports all SSD as "failed" and not free when Adaptec ASR-71605Q formats Samsung 850 pro
Answer: This is a bug of Samsung SSD 850 Pro firmware that can’t response correctly SSD cache control from the host. Areca has bypassed this issue from firmware version 1.52 date: 2014-12-19 or later. ... - 2010 to 2015: Q30011403 - Flashing disk drives attached to an Areca SAS host adapter.
Answer: User can use the CLI command to update HDD's firmware without necessary removing any single drive and upgrade. ...
The most popular searches are:
- upgrading raid card⊂mit=Search (814x)
- firmware timed out⊂mit=Search (683x)
- Greater Two TB Volume Support⊂mit=Search (645x)
- firmware+timed+out⊂mit=Search (621x)
- her coming of she coming (547x)
- hitachi failed drive⊂mit=Search (404x)
- upgrading raid card (213x)
- hitachi failed drive (186x)
- 1882⊂mit=Search (123x)
- upgrading+raid+card (119x)